Current edition approved Nov. 1, 2013. Published January 2014. Originally approved in 1994. Last previous edition approved in 2008 as D5644 – 01 (2008)ε1. — 4 p.
These test methods describe the procedures for determining average particle size distribution of recycled vulcanizate particulate.
Method A describes the Ro-tap sieve test method for 60 mesh or coarser particles.
Method B describes the ultrasonic technique combined with optical microscope especially suitable for 80 mesh or finer particles. This procedure is based on Test Method D3849.